Electrosurgical Generator/ Diathermy machine CV-2000AI LED
$4000.00 / Unit Min.order:1
★ Max 400W Electrosurgical Generator, with mono-polar and bipolar function. ★ Nine working modes: pure cut, blend1, blend2, blend3, contact coag, forced coag, soft coag, bipolar coag, bipolar cut. ★ Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.

49cm * 42cm * 18cm

9kg

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

Main Features

★  Max 400W Electrosurgical Generator, with mono-polar and bipolar function.

★  Nine working modes: pure cut, blend1, blend2, blend3, contact coag, forced coag, soft coag, bipolar coag, bipolar cut.

★  Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.

★  Microprocessor controlled, digital display. With audible and visual indicators and errors codes during the process of outputting.

★  Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue damage.

★  Both hand and foot controlled.

★  Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.

★  Memory for at least 10 frequently used programs.

★  Remote control function. The surgeon can adjust the outputs by power control ESU pencil.

★  The ESU unit can be connected with laparoscope and endoscope, etc.

★  Protection against over-voltage and over-current.

★  Defibrillation protected.

★  Convection refrigeration without ventilator.

★  Connect two monopolar instruments for simultaneous coagulation.

★  Mounted on a 4 wheels cart(optional).

★  Meets the requirements of international safety standards EN60601-1 and EN60601-2.

Technical Specifications

◆Power: 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)

◆Power rating: 1100VA±10%

◆Power Consumption: ≤1100VA

Related Power output:

Function

Working modes

Power output

(Max)

load

Frequency

V-PP

Crest

Factor

Monopolar Cut

Pure cut

400W

800Ω

512KHz

2.6kV

1.5

Blend1

300W

800Ω

4KV

1.8

Blend2

200W

800Ω

4.2KV

2.1

Blend3

150W

800Ω

4KV

2.7

Monopolar Coagulation

Spray

80W

800Ω

5.3KV

7.4

Forced

120W

800Ω

5KV

3.8

Soft

120W

800Ω

720V

1.6

Bipolar

Standard coag

70W

200Ω

1024KHz

550V

1.6

Macro-bipolar

120W

200Ω

350V

1.6

Packing list

Accessory Name

 Quantity

Main Unit

1set

Electrosurgical Pencil

5pcs

Electrosurgical Pad

10pcs

Electrosurgical pad cable

1pc

Footswitch

1set

Bipolar Forceps 

1pc

Bipolar Forceps cable

1pc

Tip Clean Sponge

1pc