Medical refrigerated freezer -40℃ -40℃ Freezer BIOBASE freezer BRF-40V450
$1687.20 / Parcel$2024.64 Min.order:1
Super Low Price
1 Scope of application The refrigerator is used to provide 2℃~8℃ storage environment, and the freezer is used to provide -10℃~-25/-40℃ storage environment, for medical institutions to store reagents, vaccines, frozen plasma and other samples. The freezer is used to provide -10℃~-25/-40℃ storage environment for medical institutions to store reagents, vaccines, frozen plasma and other samples. 2 Working environment a) Indoor only; b) Ambient temperature: 10℃~32℃; c) Relative humidity: ≤80%; d) Power supply: AC220V/50Hz; e) No strong vibration and corrosive gas around; f) No direct sunlight and other hot and cold sources. 3 Product parameters Volume: 450L Temperature range Cold room:2~8℃ / Freezer:-10~-40℃ Climate type SN/N External Dimensions 741×811×1889 (W×D×H)(mm) Noise ≤68 dB(A) Refrigerant Cold room: R290/Freezer: R290 4 Product Performance 4.1 Storage temperature The temperature of the refrigerating and freezing box is set at 5℃, and the temperature of each measuring point should not deviate from the range of 2℃~8℃ under the steady state, and the temperature inside the box should not deviate from the range of 8℃. 8℃ range, the temperature inside the box should not deviate from the range of 3.5℃~6.5℃, and the instantaneous value of the temperature at each measuring point inside the box should not be less than 0.5℃. 4.2 Characteristic point temperature The temperature at the characteristic point of the freezer ≤ -25/-40℃.4 4.3 Temperature uniformity The temperature uniformity of the freezer room should be no more than 4 (+2/-2)°C. 4.4 Temperature fluctuation 4.4 Temperature fluctuation The temperature fluctuation of the cold storage room should be no more than 4.5℃. 4.5 Temperature display (a) The temperature deviation of the display in the freezer room should be no more than 2℃. (b) The freezer room should have a device to display the temperature inside the box, the temperature display of the smallest index value of 1 ℃ or better, the display temperature and the set temperature difference should not be more than 1 ℃. The difference between the display temperature and the set temperature shall be less than 3℃. 4.6 Noise The noise level of this refrigerator/freezer is less than 68dB(A).

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

1 Scope of application The refrigerator is used to provide 2℃~8℃ storage environment, and the freezer is used to provide -10℃~-25/-40℃ storage environment, for medical institutions to store reagents, vaccines, frozen plasma and other samples. The freezer is used to provide -10℃~-25/-40℃ storage environment for medical institutions to store reagents, vaccines, frozen plasma and other samples. 2 Working environment a) Indoor only; b) Ambient temperature: 10℃~32℃; c) Relative humidity: ≤80%; d) Power supply: AC220V/50Hz; e) No strong vibration and corrosive gas around; f) No direct sunlight and other hot and cold sources. 3 Product parameters Volume: 450L Temperature range Cold room:2~8℃ / Freezer:-10~-40℃ Climate type SN/N External Dimensions 741×811×1889 (W×D×H)(mm) Noise ≤68 dB(A) Refrigerant Cold room: R290/Freezer: R290 4 Product Performance 4.1 Storage temperature The temperature of the refrigerating and freezing box is set at 5℃, and the temperature of each measuring point should not deviate from the range of 2℃~8℃ under the steady state, and the temperature inside the box should not deviate from the range of 8℃. 8℃ range, the temperature inside the box should not deviate from the range of 3.5℃~6.5℃, and the instantaneous value of the temperature at each measuring point inside the box should not be less than 0.5℃. 4.2 Characteristic point temperature The temperature at the characteristic point of the freezer ≤ -25/-40℃.4 4.3 Temperature uniformity The temperature uniformity of the freezer room should be no more than 4 (+2/-2)°C. 4.4 Temperature fluctuation 4.4 Temperature fluctuation The temperature fluctuation of the cold storage room should be no more than 4.5℃. 4.5 Temperature display (a) The temperature deviation of the display in the freezer room should be no more than 2℃. (b) The freezer room should have a device to display the temperature inside the box, the temperature display of the smallest index value of 1 ℃ or better, the display temperature and the set temperature difference should not be more than 1 ℃. The difference between the display temperature and the set temperature shall be less than 3℃. 4.6 Noise The noise level of this refrigerator/freezer is less than 68dB(A).