Nerve and Muscle Stimulator Neuromuscular electrical stimulator DB-SJ1 Neuromuscular electrophysiotherapy apparatus
$588.26471 / Parcel$705.91765 Min.order:1
Super Low Price
1、7 inch color touch screen plus rotary encoder display operation. 2、the instrument has a group of pin-plug type electric output, group electric needle output, independently controllable, without interfering with each other. 3、time setting function: time range of 0min ~ 99min adjustable, a single step of 1min. 4、Electrotherapy output parameters: 1 Each channel has 1 group of electric output, including A/B two roads, A road and B road output is opposite. The output waveform is a combination of square wave and exponential wave; 2 The pulse frequency is adjustable from 0.5 Hz to 10 Hz, with a single step of 0.1 Hz for frequencies from 0.5 Hz to 1 Hz, and a single step of 1 Hz for frequencies from 1 Hz to 10 Hz; 3 Pulse width is adjustable from 0.1ms to 10ms, with a single step length of 0.05ms when the pulse width is 0.1ms to 1ms, and a single step length of 0.5ms when the pulse width is 1ms to 10ms; 4. Output intensity: the peak value of current Ip-p is adjustable from 0mA to 99mA. 5、electroacupuncture therapy output parameters: 1 The carrier frequency is 500Hz±10%; the frequency of modulating wave is adjustable from 0.5Hz to 10Hz; when the frequency is 0.5Hz to 1Hz, the single step is 0.1Hz, and when the frequency is 1Hz to 10Hz, the single step is 1Hz, with the tolerance of ±10%; 2 Pulse width is adjustable from 0.1ms to 1ms, with a single step of 0.05ms and a tolerance of ±10%; 3 Output intensity: the therapeutic instrument electro-acupuncture each channel independent output, in 250 load impedance; each road electro-acupuncture output current peak value Ip-p from 0mA ~ 99mA adjustable, tolerance ±15%. 4 Continuous operation time is more than 8h. The output of specific low-frequency pulse current stimulates the nerves and muscles, promotes the reconstruction of neural pathways and functional recovery, can cause rhythmic muscle contraction, improve muscle strength and prevent muscle atrophy.

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

1、7 inch color touch screen plus rotary encoder display operation. 2、the instrument has a group of pin-plug type electric output, group electric needle output, independently controllable, without interfering with each other. 3、time setting function: time range of 0min ~ 99min adjustable, a single step of 1min. 4、Electrotherapy output parameters: 1 Each channel has 1 group of electric output, including A/B two roads, A road and B road output is opposite. The output waveform is a combination of square wave and exponential wave; 2 The pulse frequency is adjustable from 0.5 Hz to 10 Hz, with a single step of 0.1 Hz for frequencies from 0.5 Hz to 1 Hz, and a single step of 1 Hz for frequencies from 1 Hz to 10 Hz; 3 Pulse width is adjustable from 0.1ms to 10ms, with a single step length of 0.05ms when the pulse width is 0.1ms to 1ms, and a single step length of 0.5ms when the pulse width is 1ms to 10ms; 4. Output intensity: the peak value of current Ip-p is adjustable from 0mA to 99mA. 5、electroacupuncture therapy output parameters: 1 The carrier frequency is 500Hz±10%; the frequency of modulating wave is adjustable from 0.5Hz to 10Hz; when the frequency is 0.5Hz to 1Hz, the single step is 0.1Hz, and when the frequency is 1Hz to 10Hz, the single step is 1Hz, with the tolerance of ±10%; 2 Pulse width is adjustable from 0.1ms to 1ms, with a single step of 0.05ms and a tolerance of ±10%; 3 Output intensity: the therapeutic instrument electro-acupuncture each channel independent output, in 250 load impedance; each road electro-acupuncture output current peak value Ip-p from 0mA ~ 99mA adjustable, tolerance ±15%. 4 Continuous operation time is more than 8h. The output of specific low-frequency pulse current stimulates the nerves and muscles, promotes the reconstruction of neural pathways and functional recovery, can cause rhythmic muscle contraction, improve muscle strength and prevent muscle atrophy.