The Beckman Coulter AU400e Chemistry Analyzer is a fully automated chemistry analyzer designed for operating ease, speed, and flexibility. It uses liquid, barcoded reagents and user-friendly Microsoft Windows software. The operator is assured a fast turnaround time for response panels, maximum 800 tests per hour with the ISE, 400 tests per hour photometric.

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

Product Description

The Beckman Coulter AU400 Chemistry system, formerly the Olympus AU400 boasts over 85 assays with a maximum throughput of 400 tests per hour. The AU family of systems are well regarded, open reagent, high quality chemistry systems that are considered one of the most popular chemistry systems on the market, in particular in the US laboratory marketplace. Chemistry analyzers measure substances within bodily fluids to establish a pattern of abnormalities. The wide range of tests can be grouped under several categories such as electrolytes, enzymes, blood sugar, metabolites, thyroids, hormones, lipids, therapeutic drug monitoring, and drugs of abuse monitoring. This analysis can be conducted on blood (either whole, serum or plasma), urine, semen or cerebrospinal fluids Chemistry analysis begins with patient sample placed in separate capsules, test tubes, slides or sample cups that are transported on a conveyor with sample racks or in a carousel in a reagent tray. Specimens are sampled and then mixed automatically together with diluents and reagents in a reaction cuvette. The reagents are pulled from a reagent carousel, which is typically refrigerated to keep the reagents shelf life longer. The reactive cuvette is stored and processed in the Reaction carousel. The Reaction carousel holds the mixing station (which mixes samples and reagents) and wash station (which rinses the cuvettes). Dependent on the manufacturer, the cuvette is either made of glass or plastic, but must be optically clear so that light may pass through without any intervention from scratches or blemish. Chemistry analysis is calculated through the absorbance of the specific wavelengths as light is passed through the specimen. All chemistry analyzers possess a photometer (either filter photometer or spectrophotometer) that conducts the measurement of the light absorbance of the specimen, and results are calculated. Filter photometers use glass filters, on a rotating filter wheel, coated with colored material while spectrophotometers use prisms or gratings, to isolate these wavelengths from the scanner beam. In both cases, a lamp (typically halogen) is the light source. Spectrophotometry is a more commonly used method than Filter photometry, which is currently only used in J&J, Roche Cobas and Siemens Dimension systems. Spectraphometry is used in most other systems including Abbott, Beckman and Roche Hitachi systems. The process to attain the results from the absorbance tests are classified either as End Point or Kinetic. End point method incubates the reaction mixture for a predetermined amount of time to reach the end point, or equilibrium of the reaction. Kinetic method, as the reagents and the sample are mixed, the reaction is monitored, the rate of change in absorbance is then determined and related to analyte concentration. As such, Kinetic is a faster method than End Point.

Specifications

Assay Methodology:Single-End Point, Dual-End Point, Rate, Fixed-point
Auto Dilution:Yes
Auto Sample Handling:No
CLIA Complexity:Moderate
Configuration:Floor Model
Depth:76 cm (30 in)
Direct Sample (STAT):Yes
Height:122 cm (48 in)
Maintenance Free Electrodes:Yes
Manufacturer:Beckman Coulter
Maximum Throughput:400 tests/hour
Number of Assays:89
On-Board Refrigeration:Yes
Optical Source:

Halogen Lamp

Optical System:

Photometric

Patient Sample Capacity:80
Point Of Care:No
Power Supply:220V
Reagent Capacity:76
Reagent Delivery:Automatic Pipetting
Reagent System:Open
Reagent Type:Liquid
Sample Cycle Time:0 (sec)
Sample Input Closed Tube:No
Sample Input Type:

Sample Cups

Sample Tubes

Sample Size Max:50 μL
Sample Size Min:1 μL
Sample Types:CSF, Plasma, Urine, Serum
Series:AU
Standby Mode:Yes
Test Method:

Light Absorbancy

Water Consumption:10 (L/hour)
Water OnBoard Supply:Yes
Water Requirement:Yes
Weight:427 kg (939 lb)