Original Fujifilm Refurbished Medical Brand NX500 automatic dry-chemistry analyzer
$2867.65 / Parcel$3441.18 Min.order:1
DDP Area
A multi-purpose automatic dry-chemistry analyzer featuring remarkably short turnaround time, a touch screen interface and reliability.

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

A New Generation of Clinical Chemistry

Safety and Simplicity in Operation, Compactness, Diversity in Tests…. ALL in ONE

DRI-CHEM from FUJIFILM is a dry chemistry analyzer which can perform multiple test parameters of Clinical Chemistry. 
It has a built-in auto-pipetting system, requires no calibration*1 and no water, providing easy preparation and maintenance. The new DRI-CHEM NX500 delivers results using a simple 3-step procedure. With its quick, easy operation and compactness, 
“Real Time and Borderless” Clinical Chemistry is made possible.

*1 Except for CRP

Simple 3-step procedure

Fully Automated Procedure 
    1. Set the slide (Dry Slide Reagents). 2. Set the sample. 3. Press START. 


No Parameter Input Required 
    Information of the parameter is incorporated in the bar code printed on the back of every slide.

Easy operation by touch screen

5.7 inch VGA, 640 5 480. Qwerty touch Key board. Basic Mode / Advanced Mode are available according to user preference. 
(Basic Mode: displays operation procedure for one sample only.   Advanced Mode: displays operation procedure for one sample and measurement status for previous measured samples.) 

No pre-treatment of sample required

Plasma Filter (PF) can cut the turn around time and the pre-treatment process of the sample. It can generate plasma sample by aspirating and separating the whole blood inside the PF within 1 minute. Just set the PF on top of the sample tube and press START.

  • * PF function is available in NX500 only.
  • * TCO2: not applicable

Only 10μL/Test

Each test needs only 10μL of sample. 
(CRP needs 5μL/test, ISE needs 50μL/3 tests). Manual pipetting can be also performed when less sample available.  Less invasive for newborn at NICU.

Automatic dilution

Dilution, a time consuming process, is also automated in FUJI DRI-CHEM. Just set the ratio of dilution and press START. Dilution test also can be performed simultaneously with the regular tests, requiring no separation of tests.

No calibration required*2 QC card system

A magnetic card called QC card will adjust the lot variability in the slide reagents. 
A QC card comes with every reagent box. The analyzer memorizes the lot adjustment information once a QC card is swiped. No need to swipe QC in every measurement for the same slide lot.

  • *2 CRP: Further calibration by liquid calibrators is needed.
  •  ISE: QC card system is not used.

Calculation

The NX500 analyzer can provide results for 6 calculated parameters. No need for external calculation for commonly used parameters.

Minimize the risk of biological hazard

Slide reagents after measurement will be automatically discarded to the disposal box, minimizing the risk of contamination.

A range of sample tubes can be used

Blood Collection Tube (φ13~16 × 75~100mm) 
FUJI PLAIN TUBE (0.5mL, 1.5mL) 
FUJI HEPARIN TUBE (0.5mL, 1.5mL)

USM function

Addressing the requirement in strict laboratory management

USM (User Safety Mode) function is now introduced to 
NX500 as a selectable function.

Main features

  1. User ID registration system; Non-registered person cannot operate NX500. For this application, Operator ID Editor Kit (option item) is necessary to register and edit operator ID on your PC.          
  2. No result reporting from expired colorimetric slides.
  3. Expanded data transmission; Operator ID, Slide information (Lot/expiry) and Analyzer ID 

Accurate and reliable test results from long term and field-proven technology & experience

The FUJI DRI-CHEM slide reagent has high reliability and stability brought by fine chemical technology cultivated through the long history of FUJIFILM in photographic film manufacturing. 
Less variation of results between operators, high result reproducibility and daily precision, 
and excellent correlation with wet chemistry are its remarkable features.

IFCC standardization method (no PALP) (U/L)

Hexokinase method (mg/dL)

Emission flame method (mEq/L)

Enzymatic method (mg/dL)

Fujifilm DRI-CHEM SLIDE

Colorimetric method slide
(Enzymes, General chemistry, and Immunology)

This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.

Composition of multilayered analytical film

Potentiometric method slide
 (Electrolytes)

Each slide comes with an ion selective film electrode for each of Na, K, and Cl. Slides quantify electrolytes in the sample by a potentiometric method.

Composition of multilayered film electrode