Page 1 of 2
SF Cube three-dimensional analysis technology
BC-6900 uses unique three-dimensional cell analysis technology to achieve accurate detection of white blood cells, nucleated red blood cells, and reticulocytes and the screening of abnormal cells by analyzing forward scattered light signals, side scattered light signals, and fluorescence signals of cell particles.
Intelligent multiplication analysis technology for low-value samples
BC-6900 has an automatic judgment function that automatically increases the amount of analysis for low-value samples, thereby improving the accuracy of classification and alarming.
Eliminate interference from lipid particles
"Suspected lipid particles" affect WBC counting and analysis on the two-dimensional scatter plot. In the three-dimensional scatter plot, "suspected lipid particles" have a specific location and special shape distribution, allowing them to be accurately identified and marked, eliminating the need for Interference from other cells.
Safe and easy-to-use operating system
· The new secondary accelerated sheath flow impedance technology detects RBC and PLT, making the detection results more accurate and greatly broadening the linear range of analysis.
· The RET channel uses optical method to detect PLT to obtain PLT-O*, and PLT-I of the sheath flow impedance channel. * Mutually calibrated with the PLT-O* of the RET channel, effectively reducing the interference of small red blood cells and large platelets on PLT counting.
Fully automatic body fluid analysis function
· BC-6900 can detect cerebrospinal fluid and thoracic and ascites fluid samples. In addition to providing 7 body fluid reporting parameters (WBC-BF, TC-BF#, MN#, MN%, PMN#, PMN%, RBC-BF), it also It can provide 7 body fluid research parameters (Eos-BF#, Eos-BF%, Neu-BF#, Neu-BF%, HF-BF#, HF-BF%, RBC-BF) to provide doctors with clinical diagnosis. Valuable information.
More hematology parameters
Micro#* and Micro%* are used to display the number and proportion of
small red blood cells in the blood sample; Macro#* and Macro%* are used to display the number and proportion of large red blood cells in the blood sample;
MRV* is used to display the reticulocytes in the blood sample The average volume of
RHE* is used to display the hemoglobin content of reticulocytes in blood samples;
these new parameters are very helpful for typing anemia, especially to distinguish iron deficiency anemia from other types of anemia.
· CBC+DIFF 125 tests/hour, RET speed 90 tests/hour
· Load 100 samples at one time, and continuously add samples to be tested