Respiratory Multiple Pathogens Nucleic Acid Detection Kit (Fluorescence PCR Method) PR2022
$1.40~3.00 / Box$3.00 Min.order:1
New Products

About this item:

This product uses fluorescent PCR to detect multiple pathogens in the human respiratory tract. The reagents of this product are freeze-dried, and the active substances (enzymes, dNTPs, primer probes, etc.) required for detection are freeze-dried in the system. This product can customize the detection items according to the customer's detection needs, and can detect 30 virus targets with high sensitivity and accuracy.

12cm * 6.5cm * 6.5cm

0.1kg

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

Respiratory Multiple Pathogens Nucleic Acid Detection Kit (Fluorescence PCR Method)

This product can detect the following targets:
COVID-19 ORF1ab, COVID-19 N gene, human internal standard, influenza A virus, influenza B virus, syncytial virus (universal), enterovirus (universal), adenovirus (universal), Mycoplasma pneumoniae, rhinovirus (universal), Bocavirus, parainfluenza virus (type 1, type 2, type 3), coronavirus 229E, coronavirus NL63, coronavirus HKU1, coronavirus 0C43, Klebsiella pneumoniae, Streptococcus pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, Bordetella pertussis, Group A Streptococcus, Legionella, Chlamydia psittaci, Aspergillus, Pneumocystis jiroveci, Cryptococcus.

Product advantages:
1. Multiplex test: 

Reagents can be customized in the freeze-dried system according to the customer's test project requirements.

2. Stable and reliable:
This product is a freeze-dried PCR system. The active substances (enzymes, dNTPs, primer probes, etc.) required for detection are all freeze-dried in the detection system. It supports room temperature transportation within 1 month and has good storage stability to ensure accurate and reliable test results.
3. Fast and convenient:
The entire process of this detection reagent is completed within 90 minutes. If it is used with PCR equipment, the detection time can be shortened to 50 minutes. No manual liquid preparation and packaging is required.
4. High sensitivity:
The analytical sensitivity of this reagent is 1000 copies/mL. It includes human internal standard monitoring from sampling, nucleic acid extraction to nucleic acid detection to avoid false negatives. The detection system contains a UDG/dNTP system, which can effectively avoid false negative results caused by amplification contamination products.