Thermo Fisher 34021 400 mL Pierce TMBSubstrate kit
$404.06 / Parcel$437.21 Min.order:1
Brand Sales
34021 400 mL Pierce TMB Substrate Kit

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

TMB (3,3',5,5' tetramethylbenzidine) is a chromogen that produces blue when oxidized by hydrogen peroxide (catalyzed by HRP), with maximum absorption wavelengths at 370 and 652 nm. After adding sulfuric acid or phosphoric acid to stop the reaction, the color changes to yellow (measured at 450 nm). TMB is very sensitive and is oxidized faster than other HRP substrates, resulting in faster color development. Unlike other commercially available substrates, these products do not contain DMF or DMSO. There are three formulas, the main difference being sensitivity. Slow TMB has medium sensitivity and is suitable for kinetic readings. The sensitivity of Turbo TMB is comparable to that of approximately 1 mg/mL OPD. Ultra TMB-ELISA produces extremely high signal-to-noise ratio and sensitivity in the picogram range.

Features:

  • Ready-to-use solution
  • No hydrogen peroxide required
  • No filtration required
  • Non-carcinogenic
  • Available with different sensitivities to meet various detection requirements

1-Step TMB Substrate

  • Ready-to-use, one-component substrate
  • No hydrogen peroxide required
  • Non-carcinogenic
  • Contains no DMF or DMSO
  • Available in three formulations with different sensitivities

TMB Substrate Kit

  • More sensitive than OPD in endpoint ELISA
  • Easy to use, results in seconds
  • Upon receipt, store moisture-proof at 4°C
  • ul>

    Contains:

    TMB Substrate Kit (PI-34021): Peroxidase Substrate, 200 mL; Peroxide Solution, 200 mL< /p>

For Research Use Only. Not for use in diagnostic procedures.

1-Step Substrate is available in three formulations with different sensitivities:

  • 1-Step Slow TMB has medium sensitivity – higher sensitivity than ABTS, but lower In OPD or 1-Step Turbo TMB.
  • The sensitivity of 1-Step Turbo TMB is comparable to that of approximately 1 mg/mL OPD
  • 1-Step Ultra TMB-ELISA has extremely high signal-to-noise in the picogram range Ratio and sensitivity

References:

  1. Josephy, PD, et al. (1982).J. Biol.Chem.257(7), 3669-3675.
  2. Josephy, PD, et al. (1983).J. Biol.Chem .258(9), 5561-5569.
  3. Liem, HH, et al. (1979).Anal.Biochem. 98, 388-393.