Thermo Fisher A44360 5 mL TaqMan Fast AdvancedMaster mix (none UNG)
$853.30 / Parcel$1042.65 Min.order:1
Brand Sales
A44360 5 mLTaqMan Fast Advanced Master Mix (without UNG)

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

TaqMan Fast Advanced Master Mix provides accurate dosing and reliability in a short time. It delivers best-in-class performance in single and dual reactions, including a large quantifiable range, even for challenging targets. TaqMan Fast Advanced Master Mix contains AmpliTaq Fast DNA Polymerase, dNTPs containing dUTP, ROX dye (passive reference), and optimized buffer composition. It is available in 2X concentration. Note: TaqMan Fast Advanced Master Mix does not contain uracil-N-glycosylase (UNG). ReferenceComplete list of all TaqMan Fast Advanced Master Mix products, (with or without UNG)

TaqMan Fast Advanced Master Mix features include :
Outstanding Performance — Better sensitivity, accuracy, dynamic range and specificity than standard mixes in standard mode
Designed for Designed for enhanced benchtop stability — Stable for up to 72 hours at room temperature in prepackaged reactions
Optimized for multi-pass assays — Targets both exogenous and endogenous Duality of the original internal positive control assay kit was verified
Reduced run time (<40 minutes) on fast and standard instruments — Fast mode for fast instruments and Fast cycling conditions optimized for standard instruments
Seamless transition to experiment — Validated with TaqMan Gene Expression and microRNA Assay Kits and TaqMan Array Microfluidic Cards

Outstanding Performance
TaqMan Fast Advanced Master Mix is designed to provide performance equal to or better than standard master mixes. It has been benchmarked against standard and fast master mixes from leading vendors to help ensure best-in-class sensitivity, accuracy, dynamic range and specificity are delivered. The dynamic range of TaqMan Fast Advanced Master Mix (up to 7 log ranges) is the broadest in the industry. The figure below demonstrates the amazing sensitivity of TaqMan Fast Advanced Master Mix and TaqMan Universal PCR Master Mix by comparing the Ct values of this master mix in a panel of gene expression assay kits

Benchtop Stability, Achieve high-throughput processing and convenience
TaqMan Fast Advanced Master Mix is designed to maintain high levels of performance for up to 72 hours in prepackaged reactions. The high stability of this master mix ensures users of high-throughput liquid handling systems that the results from the first assay plate will be similar to the results from the last assay plate. The figure below shows the analysis run at the time of assembly (time 0) and after incubation for 72 hours at 30°C, simulating an extreme room temperature scenario.

For users without extremely high throughput requirements, the enhanced stability of this master mix improves the overall ease of workflow as you are no longer limited to running assay plates immediately after assembly.

Optimized for multi-pass detection
We realize that the reliability of our results is critical. TaqMan Fast Advanced Master Mix is designed to provide accurate results for dual reactions using an internal positive control (IPC). The graph below shows the results for the experimental target β-actin (gene name: ACTB), which was serially diluted and amplified in single target reactions and dual reactions.

Validated for microRNA assays
TaqMan Fast Advanced Master Mix has been validated for use in a variety of real-time PCR applications, including microRNA assays. The formulation provides high specificity and dynamic range, two critical properties that define successful results when working with microRNA. The data in the graph below shows excellent linearity of the PCR over a 6-log range of the starting template.

Shorten run time on standard instruments
TaqMan Fast Advanced Master Mix is optimized for use with both fast and standard instruments, allowing researchers who currently have standard instruments to Gain the performance benefits and efficiencies offered by this master mix. The graph below demonstrates the impressive results achieved using TaqMan Fast Advanced Master Mix on the Applied Biosystems 7300 Real-Time PCR System under rapid thermal cycling conditions. This master mix has been tested on all Applied Biosystems standard real-time PCR instruments, ensuring success whether you have a fast-start instrument or not.
For Research Use Only. Not for use in diagnostic procedures.