direct digital X-ray photography system DX-3000B
$68999.00 / Parcel Min.order:1

About this item:

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

1. Flat panel detector:

Imaging area: ≥ 17 × 17 inches (43cm × 43cm)

Detector material: amorphous silicon cesium iodide

Pixel sum: ≥ 9.4 million

Acquisition matrix: 3K × 3K(3072 × 3072)

Data transmission mode: wireless transmission

Pixel size: ≤ 139 μ M

Resolution: ≥ 3.6lp/mm

DQE:≥70%

Imaging time: ≤ 10s

A / D conversion: ≥ 16bit

Storage temperature: - 15 ℃~ 55 ℃, service temperature: 10 ℃~ 40 ℃

Flat panel detector with noise elimination technology

Calibration mode: offset calibration, gain calibration, bad pixel calibration, line noise calibration

2. Ball tube:

Tube focus: ≤ 0.6 mm / 1.2 mm

Focus power: ≥ 100kW

Anode heat capacity: ≥ 380khu

Anode target angle: 12 ° Voltage range: 40kv-150kv

Anode speed: ≥ 9500rpm

Protection device: oil pressure protection switch

3. High voltage generator

Maximum output power: 75KW

Inverter frequency: 200kHz

Output voltage: 40kV - 150kV

Maximum output Ma: ≥ 900mA

Maximum current time product: ≥ 900mas

Minimum exposure time: ≤ 1ms

Increment: ≤ 1kV regulation

Exposure mode:

Manual setting of parameters exposure mode, organ program photography mode

The photography method should be as follows:

General photography, filter photography

Power demand: 380V three phase power input

With exposure protection control device

With fault status display function

Network integration: the generator parameter status can be integrated with the collected image display

With high voltage generator shutdown protection device

4. Beam limiter

Specification: AC24 V / 100 W

Operation mode: Manual

Minimum field: < 50mm × 50mm

Radiation field (sid = 1000mm): 430mm × 430mm

Average illumination intensity: > 140lux;

Illumination ratio: > 4:1

Inherent filtration: 1.0 mmAL equivalent; Lead equivalent of shield blade: 3 MMPB (2 MMPB for middle blade)

Brightness indication time of beamer: ≥ 30 seconds

5. Inlet screen

Grid density: ≥ 80L / cm

Grid ratio: ≥ 10:1

Grating focal length: 100cm / 180cm

6. Double column multi-functional photography system

●Double column support structure

●Manual vertical / horizontal position conversion (electric auxiliary)

●Projection position: standing position, horizontal lying position and oblique position

●Transverse movement range of X-tube: 1800mm ± 50mm

●Vertical movement range of X-tube: vertical movement stroke 1500mm ± 50mm

●Rotation range of X-tube: rotation angle 0 °± 2 °~±~90°± 2 ° ●Vertical movement range of detector bracket of chest X-ray frame: 500mm ~ 1700mm ± 5%

●Stand film distance Sid: 1000mm ~ 1800mm

●The distance between film and Sid in supine position: 1000mm

● bed structure

●Four phase floating bed

●Bed surface: long × Width 2200mm × 800mm

7. Diagnostic workstation

CPU: coolong i5 4-core 3.2ghz

RAM: 4GB

Hard disk capacity: 1TB

Optical drive: DVD drive

System interface: USB, RS232, DVI / VGA / HDMI / DP, com serial port, PCI / pci-e

Display: 22 "LCD

Operating system: Windows 7 Professional Edition

Diagnostic Workstation

Workstation software function

User operation: patient information registration, multi condition query of location patient information, patient appointment, emergency department

Image processing functions: window width / window level, local automatic window width / window level, preset window width / window level, positive and negative image reversal, image reversal, rotation, image magnification and roaming, image interpolation edge enhancement, local magnification, restoration of original image, text / digital annotation, image ruler line measurement, angle measurement, brightness / contrast adjustment

Image printing: DICOM printing, paper printing, image contrast / brightness adjustment, multiple image combination printing, film size selection, print queue control

8. Medical image printer

Output film specification: 14 × 17、11 × 14、10 × 12、8 × 10 and other specifications

Output speed ≥ 80 sheets / hour

Resolution ≥ 320dpi

Film input ≥ 2 cassettes,

Gray scale resolution ≥ 14bit

DICOM3.0 interface