Disposable IBP Transducers TE 1620'S Chip 1620-H-W-T
$1.35 / Parcel Min.order:1000

About this item:

The 1620 is a fully piezo resistive silicon pressure sensor for use in invasive blood pressure monitoring. The sensor is designed to be used with automated assembly equipment and can be dropped directly into a customer's disposable blood pressure housing. The sensor is designed to meet the requirements as described in AAMI BP22 specification.

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

PRODUCT INTRODUCTION

The 1620 is a fully piezo resistive silicon pressure sensor for use in invasive blood pressure monitoring. The sensor is designed to be used with automated assembly equipment and can be dropped directly into a customer's disposable blood pressure housing. The sensor is designed to meet the requirements as described in AAMI BP22 specification.

The pressure sensor consists of a pressure sensing element mounted on a ceramic substrate. Thick film resistors on the ceramic substrate are laser trimmed for compensation and calibration. A plastic cap is attached to the ceramic substrate to provide an easy method of attachment to the customer’s assembly and protection for the sensing element. A dielectric gel is placed over the sensor to provide electrical and fluid isolation. 

The products are shipped on a tape and reel. Performance characteristics and packaging can be easily tailored on a special order basis to meet the requirements of specific customers.


ADVANTAGES

Model:1620-H-W-T
FEATURESAPPLICATIONS
Low Cost, Medical ApplicationsInvasive Blood Pressure Monitoring
Small Size and Reliable PerformanceAnesthesia department
Gel Isolation for LiquidsInterventional department
Operates from 5°C to 45°CIntensive Care Unit
Compatible for Automated AssemblyIntracranial pressure
1% Accuracy for ReplacementsKidney Dialysis Machines
5.0 uV/V/mmHg SensitivityUrodynamic test
OEM customIntrauterine pressure measuring

NOTES

1. Output of sensor with no pressure applied and a 150kΩ resistor placed across +SUPPLY to +OUTPUT. 

2. Best fit straight line. 

3. Defined as common mode symmetry between any output and supply terminal. 

4. Over an 8 hour time period after a 10 second warm-up.

5. Over operating temperature range 5°C–40°C with respect to 23°C. 

6. One discharge per minute performed by customer. 

7. Sterilization performed by customer, compatible with ETO, GAMMA, or E-Beam sterilization. 

8. After curing, meniscus of gel shall be flush to .035” [.89mm] below surface

9. This model is not suitable for surface mount operation.