Vet Anesthesia ventilator | |
Respiration mode | PCV,VCV,SPONT,DEMO |
Bellow | Big animal t:50-1600ml,small animal:0-300ml |
Screen | 9 inches touch screen |
Waveform | Pressure,Flow,Volume |
Loop | PV,PF,FV |
Tidal volume | Mechanical control:20-1600ml |
Manual control:5-1600ml | |
BPM | 1-100bpm |
I:E | 9.9:1to1:9.9 |
Inspiratory time | 0.1s-10.0s |
Apnea | 0-50% |
PEEP | Off,3-20cmH2O |
Pressure support | 5-60cmH2O |
Flow trigger | 0.5-20L/min |
Pressure trigger | -1~20cmH2O |
PSV Inspiratory terminal level | 25% |
Monitoring | Tidal volume,breathing rate,Spontaneous breathing rate,I:E,Spontaneous minute ventilation volume,Minute ventilation peak airway pressure,Average airway pressure,PEEP,Inspiratory platform pressure,FIO2 |
Alarm parameters | Tidal volume,Minute ventilation volume,Frequency,Airway pressure ,Continuous airway pressure,Negative pressure alarm,Apnea alarm,Air supply pressure failure alarm,Power supply alarm,Low battery alarm,Battery exhaustion alarm,Oxygen battery failure alarm,FIO2(optional),FICO2(optional) |
Power supply | 220V±10%,50HZ±1% |
Vet Main unit | |
Ventilation mode | Open,Closed,half-closed,half-open |
Drive mode | pneumatic |
Application | 0.5-100kg animal |
Anesthesia Vaporizer | Isoflurane,Sevoflurane,Halothane |
Oxygen Flush | 25L/min~75L/min |
Gas source pressure | Oxygen 0.25Mpa~0.65Mpa |
Trolley | High-quality aluminum alloy profile, with storage frame and special interface for exhaust gas emission |
Flowmeter | Oxygen flow meter for animals, Scale range:0~5L/min |
CO2 Absorber | |
Sodium Lime Tank Capacity | 500ml-700ml |
Absorber | The animal-specific integrated circuit can be sterilized at high temperature and high pressure at 134 ℃. The dedicated interface can be connected to an open circuit, suitable for low-flow small animals. |
Valve piece | Visible ceramic valve piece, easy to observe animal breathing. |
Pop off valve | Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags. |
Other advantage | Strong air tightness, reduce airway resistance;Design of quick replacement of sodium lime Canister |
Anesthesia Vaporizer | |
Concentration scope | Isoflurane:0.2%~5% Sevoflurane:0.2%~8% |
Flow rate scope | 0.2L/min~15L/min |
Anesthetic capacity | Dry :340ml Wet :300ml |
Mounting type | Selectatec or Cagemout |